Fast, Affordable, Versatile, Accurate Measurement Solution
DTP41 is a strip reading spectrometer that measures color with spectral technology. Whether your need is for color calibration, color process control or color management, the DTP41 autoscan spectrophotometer gives precise color measurements.
The DTP41 offers a UV model to help deal with fluorescent paper brighteners commonly found in proofing papers. Reducing the fluorescent effect from the brighteners, the UV model will assure accurate color measurement on these media.The transmission model, DTP41T, offers dual reflection and transmission capability which is an extremely versatile tool for a variety of applications including photo transparencies, research and testing.
Specifications
Measuring Geometry
Reflection 45°/0° per ANSI/ISO 5-4 (IT2.17)
Transmission 180°/0° (DTP41/T model) per ANSI/ISO 5-2 (IT2.19)
Spot Size At Sample
1.8mm (.070 in) in scan direction x 2.5mm (.097 in) wide
Light Source
Gas Pressure @ 2850°K
Spectral Sensor
DRS Technology, 24 point engine, 31 point reporting
Spectral Range
400nm to 700nm
Illuminant Types
A, C, D50, D55, D65, D75, F2, F7, F11 & F12
Standard Observers
2° & 10°
Density Responses
Status T, E, I, & A (plus Status M on DTP41/T model)
Measurement Time
Approx. 0.25 sec/patch (7mm patch)
Reflection Measurement (DTP41 & DTP41/T)
Inter-Instrument Agreement
0.3 ÆE cmc avg. typical
(avg. based on 12 BCRA tiles)
Measurement Range
0.00D to 2.50D; 0 to 160% R (reflection)
Repeatability On White
0.2 ÆE max.; ±0.01D max
Linearity
± .01D or 1%
Transmission Measurement (DTP41/T)
Inter-Instrument Agreement
0.02D or 2% typical, 0 to 3.0D
Measurement Range
0.00D to 5.00D; 0 to 110% T (transmission)
Repeatability
± 0.01D or 1%, 0 to 3.5D (visual)
Media Thickness
0.08mm (0.003 in) to 0.6mm (.025 in) for optimum scanning
Maximum Length Of Sheet
1400mm (55 in) (scanning direction)
Measuring Location (From Edge)
Columns of patches must fall within 100mm (4 in)
insert-able area on standard model, and within 225mm (9 in)
insert-able area on DTP41W9 model. Built-in guide for 35mm film
Minimum Patch Dimensions
7.0mm (.28 in) high in scan direction
12mm (.47 in) width recommended
Patch Quantities
1 minimum, 100 maximum per pass
Recommended Leader Length
38mm (1.5 in)
Minimum Footer Length
Greater of 30mm or 2 patch + 2 gap heights
Data Interface
RS-232 serial interface with baud rates from 1200 to 57.6k
communication USB
Power Required
12v DC, Universal 100–240 VAC;
50–60 Hz adapter; 30W
Calibration
Calibration strips as needed
Environmental
+10° (50°F) to +40°C (104°F) operating
30% to 85% RH non condensing
Warm-up Time
None
Physical Dimensions
Height: 88mm (3.45 in)
Width: 184mm (7.25 in)
Depth: 114mm (4.5 in)
Weight
890g (1.96 lb), DTP41/T 1090g (2.40 lb)
Accessories Provided
Calibration Reference
Interface Cable: DB9 RS-232 and/or USB
AC Adapter
Link to x-rite for related information.
dtp41 pdf manual download